PRODUCTS
SF6 high-voltage switch detection equipment
Category
Products
Air tightness testing equipment
Power Industry - Helium Leak Detection Equipment
Product Overview
Number:
Product Details
SF6 high-voltage switch detection equipment
Basic leak detection principle
According to the basic leak detection principle of helium leak detection, helium is used as a tracer gas to fill the workpiece in the vacuum box, and then the helium signal in the vacuum box is detected by the helium leak detector, so as to judge the overall leakage of the workpiece with high precision, quickly and accurately.
Basic functionality
The operator pushes the workpiece into the vacuum box, connects the quick connection joint in the vacuum box with the workpiece interface, presses the close box button, automatically closes the vacuum box door, and the system can fully automate the whole process of evacuating, large leakage detection, helium filling, micro-leakage detection, helium recovery and SF6 charging.
Basic technical indicators:
| project | parameter |
| The workpiece to be inspected | High voltage switch |
| Number of vacuum chambers | 1 pcs |
| Leakage rate | Annual leakage rate <0.1%, which translates to helium leakage rate of 1.23E-6 Pa.m3/sec |
| Beat | 1 piece per hour |
| Tracer gas | Helium |
| Helium pressure check | 0.5bar |
| SF6 charging pressure | 0.14MPa (absolute pressure) |
keyword:
detection equipment
SF6 High voltage switch
Power switch
Switch detection
Helium leak detection
Related Products
undefined
Online Message
We have a professional customer team to provide you with 7 * 24 services
Online Message